Laboratory Information Management System (standalone)

Laboratory Information Management System (standalone) — specifications, sample/test golden flow, OOS flow, and COA issuance (Golden Demo #5).

This reference implementation is explored via internal system login rather than a public website — everything below is real, verified detail about what it actually contains.

What this demo proves

8 real, documented test scenarios verified against this reference implementation, including:

  • A duplicate sample (same batch, type, and date) is blocked
  • Testing against a Draft (not yet approved) specification is blocked
  • An analyst can't review their own test result (segregation of duties)
  • Pass/fail is always recomputed server-side from spec limits, never trusted from manual entry
  • An out-of-spec result automatically creates a linked QMS out-of-spec record
  • A reviewed test result can't be silently edited afterward
  • A Certificate of Analysis can only be approved once its test is Approved
  • Testing on an instrument with overdue calibration is blocked

Business flow

The standalone LIMS runs a full sample lifecycle — receive, assign, test, record result, review, approve — for a Paracetamol tablet batch, then deliberately produces an out-of-spec assay result to prove it automatically raises a real linked quality record, finally issuing a Certificate of Analysis once the test is Approved.

Real issues found while building this demo

Radical transparency: these are real engineering incidents from this demo's own build, not illustrative examples.

  • An automated quality-event hook updated the very document that triggered it from inside its own save event, causing a timestamp-conflict error and a real partial-write incident.
  • A later, unrelated demo's reuse of the same shared analyst account broke this demo's own segregation-of-duties check by matching the wrong specification — fixed by scoping the check explicitly.
Engineering Evidence

For technical reviewers: the exact test IDs, seed data steps, and platform engines behind the claims above. Click to expand.

Golden Demo #5

Every test ID and what it verifies:

  • L01A duplicate sample (same batch, type, and date) is blocked
  • L02Testing against a Draft (not yet approved) specification is blocked
  • L03An analyst can't review their own test result (segregation of duties)
  • L04Pass/fail is always recomputed server-side from spec limits, never trusted from manual entry
  • L05An out-of-spec result automatically creates a linked QMS out-of-spec record
  • L06A reviewed test result can't be silently edited afterward
  • L07A Certificate of Analysis can only be approved once its test is Approved
  • L08Testing on an instrument with overdue calibration is blocked

Real seed data steps

5 real seed steps ran, in order, to build this reference demo's data:

  1. 10LIMS Master Data (DP-537)Master data
  2. 20LIMS Golden Flow L04 (DP-538)Transaction
  3. 30LIMS OOS Flow L05 (DP-539)Transaction
  4. 40LIMS COA L07 (DP-540)Transaction
  5. 50LIMS Validations L01/L02/L03/L06/L08 (DP-541)Transaction